50W Single Output Switching Power SupplyLRS-50 rige
Universele AC-ynfier / folslein berik
Standert 300VAC surge input foar 5 sekonden
Beskermingen: Kortsluting / Overload / Overspanning
Cooling troch frije lucht konveksje
LED-yndikator foar macht oan
100% folsleine load burn-in test
Hege wurktemperatuer oant 70 ℃
Hege effisjinsje, lange libben en hege betrouberens
2 jier garânsje
SPESIFIKASJE | |||||||
OUTPUT | |||||||
Model | LRS-50-3.3 | LRS-50-5 | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-36 | LRS-50-48 |
DC spanning | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Aktueel | 10A | 10A | 4.2A | 3.4A | 2.2A | 1.45A | 1.1A |
Aktuele Range | 0~10A | 0~10A | 0~4.2A | 0~3.4A | 0~2.2A | 0~1.45A | 0~1.1A |
Rated Power | 33W | 50W | 50.4W | 51W | 52.8W | 52.2W | 52.8W |
Ripple & Noise | 80mVp | 80mVp | 120 mVp-p | 120 mVp-p | 150 mVp-p | 200 mVp-p | 200 mVp-p |
Voltage Adj.Berik | 2.97~3.6V | 4.5 ~ 5.5V | 10.2~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
Voltage Tolerânsje | ±3,0% | ±2.0% | ±1,0% | ±1,0% | ±1,0% | ±1,0% | ±1,0% |
Line Regeling | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% |
Load Regeling | ±2.0% | ±1,0% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% |
Setup, Rise Time | 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC by folsleine lading | ||||||
Hold Up Tiid | 30ms/230VAC 12ms/115VAC by folsleine lading | ||||||
YNFIER | |||||||
Voltage Range | 85 ~ 264VAC 120~375VDC | ||||||
Frekwinsjeberik | 47 ~ 63 Hz | ||||||
Effisjinsje | 80% | 83% | 86% | 88% | 89% | 90% | |
AC Strom | 0.95A/115VAC 0.56A/230VAC | ||||||
Inrush Current | Kâlde start 45A / 230VAC | ||||||
Leakage Strom | <0.75mA / 240VAC | ||||||
BESKERMING | |||||||
Over Load | 110 ~ 150% rated útfierkrêft | ||||||
Beskermingstype: Hiccup-modus, herstelt automatysk neidat de foutbetingst is fuorthelle | |||||||
Over Voltage | 3.8~4.45V | 5.9~7.3V | 13.8 ~ 16.2V | 18.75~21.75V | 41.4~48.6V | 55.2~64.8V | |
Beskermingstype: o / p-spanning ôfslute, opnij oansette om te herstellen | |||||||
MILJEU | |||||||
Wurk Temp. | -30 ~ +70 ℃ (ferwize nei "derating curve") | ||||||
Working Feuchte | 20 ~ 90% RH net-kondensearjend | ||||||
Storage Temp., Feuchte | -40 ~ +85 ℃, 10 ~ 95% RH | ||||||
Temp.Koëffisjint | ±0.03%/℃ (0 ~ 50℃) | ||||||
Vibraasje | 10 ~ 500Hz, 5G 10min./1syklus, 60min.elk lâns X, Y, Z assen | ||||||
SAFETY & EMC | |||||||
Safety Standards | UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 goedkard | ||||||
Standert spanning | I/PO/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||
Isolaasje ferset | I/PO/P, I/P-FG, O/P-FG: 100M Ohm / 500VDC / 25℃ / 70% RH | ||||||
EMC Emission | Konformiteit oan EN55022(CISPR22), GB9254 KLASSE B, EN55014 EN 61000-3-2,-3 | ||||||
EMC immuniteit | Konformiteit oan EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), nivo fan swiere yndustry, kritearia A | ||||||
OTHERS | |||||||
Diminsje | 99*82*30mm (L*W*H) | ||||||
Gewicht | 0,23 kg | ||||||
Packing | 60pcs/carton/14.8kg/0.88CUFT | ||||||
NOAT | |||||||
1. Alle parameters NET spesjaal neamd wurde mjitten op 230VAC input, rated load en 25 ℃ fan ambient temperatuer. | |||||||
2. Ripple & lûd wurde mjitten op 20MHz fan bânbreedte troch it brûken fan in 12" twisted peardraad beëinige mei in 0.1uf & 47uf parallelle kondensator. | |||||||
3. Tolerânsje: omfiemet opset tolerânsje, line regeljouwing en load regeljouwing. | |||||||
4. Line regeljouwing wurdt metten fan lege line nei hege line by rated load. | |||||||
5. Loadregeling wurdt mjitten fan 0% oant 100% rated load. | |||||||
6. De macht oanbod wurdt beskôge as in komponint dat wurdt ynstallearre yn in lêste apparatuer.De definitive apparatuer moat opnij befêstige wurde dat it noch foldocht oan EMC-rjochtlinen. | |||||||
7. Lengte fan opset tiid wurdt metten by kâlde earste start.It ON / OFF fan 'e stroomfoarsjenning heul rap kin liede ta fergrutting fan' e opsettiid. |